Wind Power

Reduced iron levels and lower PQ index

A 1.5 MW wind turbine gearbox showed persistent contamination risk despite routine oil analysis. To understand the true internal condition of the gearbox, debris captured inside an offline filtration unit was analysed after extended in-service operation. Standard oil samples alone were not showing the full extent of varnish, wear debris, and moisture present within the system.  

View Case Study
About us - Delta-xero

Significant O&M cost reduction

A wind farm operating 117 × GE 1.5 MW wind turbines faced high ongoing costs from regular gearbox oil changes every ~4 years, including oil flushing, downtime, labour, and disposal. Oil analysis showed that standard inline filtration was not sufficient to manage varnish, sludge, moisture, and long-term contamination buildup in aging gearboxes.  

View Case Study
Oil Life Extension Case Study

Oil restored to “as good as new” condition

A 2MW wind turbine gearbox had its oil condemned for disposal after 10 years in service. The 320 cSt synthetic gearbox oil showed severe varnish formation, extremely high particle counts, and degraded cleanliness, making reuse impossible under normal maintenance standards. The oil was scheduled for disposal, with full replacement costs unavoidable.  

View Case Study
Wind Turbine Gearbox Oil Restored to 'As Good As New'

Metallic debris and varnish residues removed

A Bonus 300 kW wind turbine gearbox with over 10 years of operation showed persistent oil discolouration and internal contamination, even after repeated oil changes and flushing. New oil was observed to degrade rapidly, indicating legacy varnish and debris within the gearbox that conventional maintenance could not remove.  

View Case Study
Oil Life Extension Case Study

ORE Catapult Fujin HPU: 80–85% Less Downtime

ORE Catapult's Fujin wind industry test rig had varnish, carbon and aluminium debris in its HPU oil despite a 3 µm inline filter. Delta-Xero offline filtration removed over 24 kg of contamination in six months and cut downtime by 80–85%.

View Case Study
Offshore wind farm at sunrise with turbines standing in calm sea

Siemens 1.3 MW Wind Turbine: 84% Less Gearbox Oil Varnish

A Siemens 1.3 MW wind turbine gearbox had high particles, moisture and varnish at ISO 21/18/11. A wall-mounted Delta-Xero DX1001-W cleaned the oil in service, cutting I-MPC from 23.2 to 3.6, water by 68% and >4 µm particles by 98.4%.

View Case Study
Close-up of a wind turbine nacelle and rotor hub against a blue sky

Senvion MM82 Wind Turbine: Gearbox Oil Restored in Five Months

A Senvion MM82 2 MW wind turbine gearbox oil was rated severity 4, with high water, iron and acid number. A Delta-Xero DX1001-W restored it to severity 1 in five months: 71% fewer >4 µm particles, 56% less water and 65% less iron.

View Case Study
Onshore wind turbines across green rolling hills