Siemens 1.3 MW Wind Turbine: 84% Less Gearbox Oil Varnish

Gearbox oil varnish on a Siemens 1.3 MW wind turbine: I-MPC down 84% and >4 µm particles down 98.4%, with the turbine in service.

Close-up of a wind turbine nacelle and rotor hub against a blue sky
case study

How continuous offline filtration removed varnish from a wind turbine gearbox

The Challenge

Oil analysis from January 2024 found high particle contamination, moisture and varnish in the T1 gearbox of a Siemens 1.3 MW wind turbine operated by a confidential wind farm operator. Cleanliness was ISO 21/18/11, with 18,991 particles per mL above 4 µm and 1,510 above 6 µm. Water measured 201 ppm, insoluble MPC (I-MPC) was 23.2, soluble MPC (S-MPC) was 21.8 and MPC weight was 0.0108 g. Viscosity at 40°C was 296 cSt and was flagged for monitoring.

The Solution

A Delta-Xero DX1001-W wall-mounted unit continuously circulated the gearbox oil through offline cellulose filtration, removing fine particulate, moisture and varnish while the turbine remained in service.

Samples from January 2024 and March 2025 were compared for particle count, Karl Fischer water, viscosity, acid number, insoluble and soluble MPC, MPC weight and ferrographic micropatch analysis. Because the sampling point sits upstream of the filter, varnish released from internal surfaces can temporarily appear in samples during the cleaning process.

The Results

  • Varnish removed: I-MPC fell by 84% from 23.2 to 3.6, S-MPC by 50% to 10.9 and MPC weight by 75%.

  • Fine particles: particles above 4 µm fell by 98.4% (18,991 to 299 per mL) and above 6 µm by 92.5%.

  • Cleaner oil: ISO cleanliness improved from 21/18/11 to 15/14/11.

  • Less moisture: water fell by 68% from 201 to 65 ppm.

  • Ferrography: 100x micropatches showed far fewer wear, abrasive and varnish particles in March 2025.

Metric

Jan 2024

Mar 2025

Change

ISO cleanliness

21/18/11

15/14/11

6 / 4 / 0 codes

>4 µm particles /mL

18,991

299

98.4% lower

>6 µm particles /mL

1,510

114

92.5% lower

Water

201 ppm

65 ppm

68% lower

I-MPC

23.2

3.6

84% lower

S-MPC

21.8

10.9

50% lower

Download the full Siemens 1.3 MW gearbox oil case study for the ferrography and MPC evidence.

Related Case Studies

About us - Delta-xero

Reduced iron levels and lower PQ index

A 1.5 MW wind turbine gearbox showed persistent contamination risk despite routine oil analysis. To understand the true internal condition of the gearbox, debris captured inside an offline filtration unit was analysed after extended in-service operation. Standard oil samples alone were not showing the full extent of varnish, wear debris, and moisture present within the system.  

View Case Study
Off-shore Oil and Gas: Case Study 2

The Additive Myth Debunked

A long-term independent study was carried out by POLARIS Laboratories Europe to assess whether installing Delta-Xero filtration on a landfill gas engine would negatively affect lubricant condition, additive performance, or expected oil drain intervals.

View Case Study
contact us

Ready to transform your oil management?