Energy: Power & Wind

Protecting critical assets in power generation. We help plants operate cleaner and longer by cutting waste and improving energy efficiency across every stage of production—from wind towers to turbine halls.

Delta-Xero 0.1-micron filtration system for wind turbine gearboxes to prevent bearing spalling and gear wear

01

Your Turbines & High-Load Gearboxes (Gas/Steam Turbines, Wind Turbines & Power Generation Hubs)

APPLICATIONS

  • Main turbine bearings and control system

  • Wind turbine gearboxes and pitch/yaw control

  • Hydraulic start-up systems and auxiliary drives

THE PROBLEM

  • High pressure and heat accelerate oil degradation and additive depletion

  • Fine particulates, varnish (oxidation by-products), and moisture build up over time

  • Contamination causes valve sticking, actuator lag, and unstable control

  • Downtime and maintenance costs rise with frequent unplanned stops

Delta-Xero solves this by
  • Removing sub-micron particulates, varnish, water, siloxane, and salts

  • Maintaining hydraulic oil cleanliness well below ISO 4406 limits

  • Extending oil life and reducing component wear on sensitive servo-valves

  • Improving hydraulic responsiveness and system reliability through continuous offline filtration

Turbine lube oil varnish removal system to reduce MPC levels and prevent unscheduled turbine trips

02

Gas & Steam Turbines Turbine Lube Oil & EHC Control Oil Systems

APPLICATIONS
  • Gas and steam turbine main bearing lubrication circuits

  • Electro-hydraulic control (EHC) and governor systems

  • Turbine lube oil coolers and heat exchangers

  • Combined cycle power plant auxiliary systems

THE PROBLEM
  • Extreme load cycling causes rapid oil oxidation and moisture ingress

  • Sub-micron wear particles cause micro-pitting and bearing spalling

  • Standard filters miss the fine silt driving the most significant gear damage

  • Offshore repairs carry astronomical costs and extended revenue loss

DELTA-XERO SOLVES THIS BY
  • Remove moisture and oxidation by-products offline down to 0.1 micron

  • Maintain oil in 'clean and dry' condition to reduce gear wear and micro-pitting

  • Extend intervals between expensive oil changes in remote or offshore assets

  • Support condition-based maintenance to maximise energy capture and ROI

Offline kidney-loop filtration for power plant auxiliary pumps and gearboxes to remove moisture and solids

03

Pumps, Compressors & Auxiliary Gearboxes Power Plant Balance-of-Plant & Auxiliary Drive Systems

APPLICATION
  • Boiler feed pumps and cooling water pump drives

  • Air and gas compressors in power plant auxiliary circuits

  • Auxiliary gearboxes for ID/FD fans and cooling towers

  • Water treatment plant pump and drive systems

THE PROBLEM
  • Water and particle ingress cause rapid oil degradation in auxiliary systems

  • Valve sticking and reduced pump efficiency interrupt the generation process

  • Minor' component failures cascade into full plant stoppages

  • High service frequency drives up the total cost to serve for critical infrastructure

DELTA-XERO SOLVES THIS BY
  • Remove moisture, varnish, and solids offline without interrupting plant operation

  • Protect seals, bearings, and gears from abrasive contamination-driven wear

  • Extend both asset life and oil life to lower overall maintenance spend

  • Reduce the cost to serve for critical power plant auxiliary infrastructure

Precision hydraulic oil conditioning for wind turbine pitch and brake systems to ensure fail-safe valve actuation

04

Hydraulic Control Systems Turbine Pitch, Brake & Valve Actuation Hydraulics

APPLICATION
  • Wind turbine pitch and brake hydraulic systems

  • Turbine governor and flow-control valve actuators

  • Emergency shutdown (ESD) hydraulic systems

  • Grid-connected power plant safety interlocks

THE PROBLEM
  • Varnish and water cause slow actuation or jamming of precision control valves

  • Delayed hydraulic response during peak events creates regulatory safety risk

  • Contaminated ESD systems cannot meet fail-safe actuation requirements

  • Emergency shutdowns expose contamination-induced valve drift under scrutiny

DELTA-XERO SOLVES THIS BY
  • Remove fine contamination and moisture without requiring system downtime

  • Maintain precision valve response for fail-safe operation at all times

  • Support safety-critical hydraulic reliability through continuous oil polishing

  • Extend service intervals for the most critical hydraulic assets on the grid

High-capacity fuel filtration for data centre and hospital backup generators ensuring 100% equipment availabilit

05

Standby Generation Data Centre, Hospital & Critical Infrastructure Backup Power

APPLICATION
  • Hospital emergency backup diesel generators

  • Data centre UPS and standby genset fuel systems

  • ational Grid and DNO critical infrastructure power

  • Tier-1 mission-critical facility standby power reserves

THE PROBLEM
  • Long idle periods cause diesel fuel instability and microbial growth (diesel bug)

  • Water condensation in bulk tanks enables biomass that plugs filters at cold start

  • Lubricant varnish from thermal cycling causes poor load response under emergency

  • Failure to start in a mission-critical facility is a catastrophic, unacceptable risk

DELTA-XERO SOLVES THIS BY
  • Reduce diesel contamination by 99.8% and water by 99.5% through tank filtration

  • Eliminate diesel bug to guarantee fuel readiness after extended storage periods

  • Keep engine oils clean, dry, and varnish-free during prolonged standby

  • Ensure 100% genset availability for hospitals, data centres, and critical networks

contact us

Ready to transform your oil management?