case study

How offline filtration cleaned the Fujin test rig hydraulic oil that a 3 µm filter missed

The Challenge

ORE Catapult asked Delta-Xero to assess the Mobil DTE 10 Excel hydraulic oil in the hydraulic power unit (HPU) of its Fujin wind industry test rig in the UK. Despite an existing 3 µm inline filter, the oil contained high particle levels, varnish, solid carbon deposits, aluminium debris and evidence of electrostatic discharge, putting sensors, actuators, strainers and filters at risk.

The Solution

A controlled 25 litre on-site trial ran for approximately 23 hours using a mobile Delta-Xero DX1001-T-MP-VFD unit with 0.1 µm filtration capability. Cold oil at 13–20°C limited flow to around 0.2 litres per minute.

Samples were taken before filtration, after four hours and after about 23 hours. Customer and Delta-Xero particle counters were compared, 0.45 µm micropatches were checked, and independent laboratories tested viscosity and additive chemistry. Following the trial, ORE Catapult installed a permanent DX1006-T-MP-VFD on the Fujin HPU and later acquired a second unit.

The Results

  • Rapid cleaning: particle readings fell substantially within four hours, and the 0.45 µm patch was clear after about 23 hours.

  • Oil integrity: independent laboratory analysis confirmed no detrimental effect on viscosity or additive chemistry.

  • Contamination removed: more than 24 kg of sludge, varnish and contamination was captured in the first six months.

  • Operational impact: technical interventions and downtime fell by 80–85%, with estimated payback in under two weeks.

Download the full ORE Catapult Fujin HPU case study for the trial data and micropatch evidence.

Related Case Studies

About us - Delta-xero

Reduced iron levels and lower PQ index

A 1.5 MW wind turbine gearbox showed persistent contamination risk despite routine oil analysis. To understand the true internal condition of the gearbox, debris captured inside an offline filtration unit was analysed after extended in-service operation. Standard oil samples alone were not showing the full extent of varnish, wear debris, and moisture present within the system.  

View Case Study
Off-shore Oil and Gas: Case Study 2

The Additive Myth Debunked

A long-term independent study was carried out by POLARIS Laboratories Europe to assess whether installing Delta-Xero filtration on a landfill gas engine would negatively affect lubricant condition, additive performance, or expected oil drain intervals.

View Case Study
contact us

Ready to transform your oil management?