Senvion MM82 Wind Turbine: Gearbox Oil Restored in Five Months

Wind turbine gearbox oil from severity 4 to severity 1 in five months, with no oil change and no downtime.

Onshore wind turbines across green rolling hills
case study

How a wall-mounted DX1001-W restored wind turbine gearbox oil in service

The Challenge

In May 2024, oil analysis rated the T29 gearbox oil on a Senvion MM82 2 MW wind turbine at severity 4. Cleanliness was ISO 18/16/12, with 2,196 particles per mL above 4 µm, 587 above 6 µm and 37 above 14 µm. Water measured 386 ppm, iron was elevated at 68 ppm and the acid number was 6.20. Viscosity (316 cSt) was within the ISO VG 320 range and MPC was low at 3.2.

The Solution

A wall-mounted Delta-Xero DX1001-W continuously circulated the gearbox oil through offline filtration while the turbine stayed in service, targeting fine particulate, moisture and oxidation by-products without chemical treatment or an oil change.

Polaris Laboratories independently compared samples from May and November 2024, covering ISO 4406 particle count, Karl Fischer water, wear and additive metals, viscosity, acid number and MPC.

The Results

  • Severity 4 to severity 1: overall oil condition improved after five months of filtration.

  • Fewer particles: >4 µm particles fell by 71%, >6 µm by 72% and >14 µm by 57%; ISO cleanliness improved from 18/16/12 to 17/15/11.

  • Less water and acid: water fell by 56% (386 to 171 ppm) and acid number by 41% (6.20 to 3.66).

  • Less wear: iron fell by 65% from 68 to 24 ppm.

  • Oil protected: viscosity stayed within ISO VG 320 at 324 cSt, additive metals were stable and MPC stayed low.

Metric

May 2024

Nov 2024

Change

>4 µm particles /mL

2,196

641

71% lower

>6 µm particles /mL

587

167

72% lower

>14 µm particles /mL

37

16

57% lower

Water

386 ppm

171 ppm

56% lower

Iron

68 ppm

24 ppm

65% lower

Acid number

6.20

3.66

41% lower

Download the full Senvion MM82 gearbox oil case study for the Polaris laboratory comparison.

Related Case Studies

About us - Delta-xero

Reduced iron levels and lower PQ index

A 1.5 MW wind turbine gearbox showed persistent contamination risk despite routine oil analysis. To understand the true internal condition of the gearbox, debris captured inside an offline filtration unit was analysed after extended in-service operation. Standard oil samples alone were not showing the full extent of varnish, wear debris, and moisture present within the system.  

View Case Study
Off-shore Oil and Gas: Case Study 2

The Additive Myth Debunked

A long-term independent study was carried out by POLARIS Laboratories Europe to assess whether installing Delta-Xero filtration on a landfill gas engine would negatively affect lubricant condition, additive performance, or expected oil drain intervals.

View Case Study
contact us

Ready to transform your oil management?