How cleaner diesel cut toxic exhaust emissions on a dockside crane

The Challenge

Portico Shipping operates multi-million-pound Gottwald Terex dockside cranes at Portsmouth International Port, powered by Cummins diesel engines for electrical and hydraulic power. Critical diesel cleanliness put injectors and pumps at risk and increased exhaust toxicity. Portico also wanted to know whether removing fuel contamination could measurably reduce harmful exhaust emissions.

The trial needed repeatable real-world testing: the crane was set aside between tests, the same 8.9 tonne test load was used, and operating modes were closely controlled.

The Solution

A Delta-Xero DX1002-T was connected to crane 7’s main fuel tank in a continuous offline loop, with an MP Filtri ICM 2 providing real-time ISO 4406 cleanliness data. Emissions were measured before and after filtration with a calibrated TESTO 350 gas analyser at idle, full load, and full load with simultaneous boom lift and slew, covering CO, NO2, NOx, NO and SO2.

The Results

  • Cleaner fuel: particles larger than 4 µm fell by 99.5%, 6 µm by 99.7% and 14 µm by 99.9%.

  • Lower emissions: every measured exhaust gas fell, with NO2 down by up to 72.4% at full load with boom movement.

  • Reliability: cleaner diesel reduced the risk to injectors and fuel pumps.

  • Longer filter life: Portico reported at least a three-fold extension in filter life.

  • Fleet adoption: results led to further installations across the crane fleet.

Gas

Mean

Idle

Full load

Full load + boom

CO

22.2%

33.1%

6.7%

26.7%

NO2

53%

45.3%

41.4%

72.4%

NOx

20.9%

8.3%

9.6%

44.7%

NO

43.3%

50.0%

20.0%

60.0%

SO2

23.3%

15.7%

9.6%

44.7%

“Since fitting Delta-Xero systems our crane downtime has reduced significantly and the life of our filters has been extended three-fold. The higher quality of fuel and oil gives health and environmental benefits.” Robert Scribbins, Engineering Manager, Portico Shipping Ltd.

Download the full Portico dockside crane diesel case study for the complete emissions data.

Related Case Studies

About us - Delta-xero

Reduced iron levels and lower PQ index

A 1.5 MW wind turbine gearbox showed persistent contamination risk despite routine oil analysis. To understand the true internal condition of the gearbox, debris captured inside an offline filtration unit was analysed after extended in-service operation. Standard oil samples alone were not showing the full extent of varnish, wear debris, and moisture present within the system.  

View Case Study
Off-shore Oil and Gas: Case Study 2

The Additive Myth Debunked

A long-term independent study was carried out by POLARIS Laboratories Europe to assess whether installing Delta-Xero filtration on a landfill gas engine would negatively affect lubricant condition, additive performance, or expected oil drain intervals.

View Case Study
contact us

Ready to transform your oil management?