Ship engine room with a marine diesel engine, pipework and gauges

Marine Engine Lube Oil: 92% Fewer Particles in 528 Hours

Marine engine lube oil filtration on a tanker: 92% fewer >4 µm particles in 528 hours, alongside the existing purifiers.

Ship engine room with a marine diesel engine, pipework and gauges
case study

How DX Powertrain filtration cleaned marine engine lube oil that purifiers could not

The Challenge

Electronically controlled marine engines rely on clean lubricating oil to protect the camshaft and associated components as speed and load change. On a tanker in a major Greek shipping company’s fleet, oil analysis showed particle levels in the main engine camshaft lubrication system above recommended limits, despite the vessel’s existing onboard filtration and purification equipment. Fine contamination stayed in circulation, increasing the risk of abrasive wear.

The operator needed treatment that could run continuously while the engine was in service and remove fine particulate, moisture and varnish-related contamination.

The Solution

On the recommendation of Hexagon Europe, a Delta-Xero DX1001 offline filtration unit was installed in a continuous kidney loop. Its DX Powertrain submicron cellulose media worked alongside the existing treatment systems.

Oil samples were analysed over 528 operating hours, tracking particle concentrations at >4, >6 and >14 µm and the ISO 4407 cleanliness code.

The Results

  • 91.8% fewer fine particles: >4 µm particles fell from 2,994 to 246 per mL.

  • Across all sizes: >6 µm particles fell by 90.9% and >14 µm by 88.3%.

  • Cleaner oil: ISO cleanliness improved from 19/19/16 to 15/15/13.

  • Water removed: water content was reported at 0% after filtration.

Metric

Initial

After 528 h

Change

>4 µm particles /mL

2,994

246

91.8% lower

>6 µm particles /mL

2,700

246

90.9% lower

>14 µm particles /mL

640

75

88.3% lower

ISO 4407 code

19/19/16

15/15/13

4 / 4 / 3 codes

“The filter can rapidly eliminate contaminants, including varnish, that SFF and purification methods cannot.” Fleet technical manager.

Case study supplied by Hexagon Europe. Download the full marine engine lube oil case study for the complete data.

Related Case Studies

About us - Delta-xero

Reduced iron levels and lower PQ index

A 1.5 MW wind turbine gearbox showed persistent contamination risk despite routine oil analysis. To understand the true internal condition of the gearbox, debris captured inside an offline filtration unit was analysed after extended in-service operation. Standard oil samples alone were not showing the full extent of varnish, wear debris, and moisture present within the system.  

View Case Study
Off-shore Oil and Gas: Case Study 2

The Additive Myth Debunked

A long-term independent study was carried out by POLARIS Laboratories Europe to assess whether installing Delta-Xero filtration on a landfill gas engine would negatively affect lubricant condition, additive performance, or expected oil drain intervals.

View Case Study
contact us

Ready to transform your oil management?