Engine Test Facility: From Oil Disposal to Oil Reuse

From single-use test oil to conditioned oil reuse at a UK marine engine test facility.

case study

How continuous oil conditioning made test-cell oil reusable

The Challenge

At a UK test facility, a confidential marine diesel propulsion manufacturer filled each engine with a precise charge of new OEM-approved oil before final load testing. After every test the sump was drained and the oil disposed of. The customer wanted to reuse oil across multiple test runs to reduce waste, carbon footprint and cost, but only if oil condition could be controlled and engine protection was not compromised.

The Solution

Delta-Xero developed a portable trolley system with a barrel and flow meters to meter oil into and out of the engine, while a DX1001-W continuously conditioned the barrel oil in a kidney loop. Particle and relative humidity monitoring were supported by laboratory samples.

When flow through the filter proved too slow for test-cell timescales, a separate transfer pump was added for delivery and recovery, leaving the DX1001-W dedicated to continuous conditioning. The successful mobile trial then progressed to a permanent two-barrel installation in a bunded area, later enhanced with Spectrolytic online oil analysis for real-time condition data.

The Results

  • Oil reuse: the process changed from disposal after every test to conditioned reuse across multiple engine tests.

  • Lower cost and carbon: significant oil-life extension, reduced oil cost and a lower carbon footprint.

  • Faster turnaround: a separate transfer pump sped up delivery and recovery while filtration continued independently.

  • Permanent system: the mobile trial progressed to a permanent two-barrel, bunded installation.

  • Condition assurance: particle and humidity monitoring, followed by Spectrolytic analysis, support continued-use decisions.

Download the full engine test facility oil recovery case study for the project images and system details.

Related Case Studies

About us - Delta-xero

Reduced iron levels and lower PQ index

A 1.5 MW wind turbine gearbox showed persistent contamination risk despite routine oil analysis. To understand the true internal condition of the gearbox, debris captured inside an offline filtration unit was analysed after extended in-service operation. Standard oil samples alone were not showing the full extent of varnish, wear debris, and moisture present within the system.  

View Case Study
Off-shore Oil and Gas: Case Study 2

The Additive Myth Debunked

A long-term independent study was carried out by POLARIS Laboratories Europe to assess whether installing Delta-Xero filtration on a landfill gas engine would negatively affect lubricant condition, additive performance, or expected oil drain intervals.

View Case Study
contact us

Ready to transform your oil management?