Steam turbine hall inside a thermal power station

CAN2 Termik Turbine: 21.9 kg Removed From EHC Fluid

EHC fluid restoration on a steam turbine: 21.9 kg of contamination removed and soluble MPC down 58% in six days.

Steam turbine hall inside a thermal power station
case study

How continuous filtration pulled varnish out of a turbine EHC system

The Challenge

The turbine electrohydraulic control (EHC) system at the CAN2 Termik thermal power station contained aged Shell DR46 fluid that was heavily contaminated with clear varnish and carbon-coloured deposits associated with microdieseling.

Laboratory trends for MPC, particle count, water and acid number fluctuated as contamination stuck to reservoir and control-system surfaces was mobilised, making it hard to tell contamination removal apart from fresh fluid degradation.

The Solution

Delta-Xero installed a six-cartridge offline filtration system to circulate the Shell DR46 continuously. Particle count, insoluble MPC (I-MPC), soluble MPC (S-MPC) and 0.8 µm ferrographic micropatches were trended together so changes in contamination type and level could be followed.

As the fluid became undersaturated, it drew residual varnish from internal surfaces. Cartridges were changed as they loaded, because saturated media still removes particles but removes less water and varnish.

The Results

  • 21.9 kg of contamination removed across six cartridges in five months. One cartridge alone held 3.64 kg.

  • Rapid varnish reduction: between 11 and 17 June 2022, I-MPC fell from 57.7 to 47.8 (17%) and S-MPC from 19.1 to 8.0 (58%).

  • Sharp particle reduction after the cartridge change on 10 June.

  • Cleaner, stable fluid: by March 2023, I-MPC was 8.8 and S-MPC 8.7.

The trial also showed how important timely cartridge replacement is for EHC varnish control. Download the full EHC fluid case study for the MPC and micropatch evidence.

Related Case Studies

About us - Delta-xero

Reduced iron levels and lower PQ index

A 1.5 MW wind turbine gearbox showed persistent contamination risk despite routine oil analysis. To understand the true internal condition of the gearbox, debris captured inside an offline filtration unit was analysed after extended in-service operation. Standard oil samples alone were not showing the full extent of varnish, wear debris, and moisture present within the system.  

View Case Study
Off-shore Oil and Gas: Case Study 2

The Additive Myth Debunked

A long-term independent study was carried out by POLARIS Laboratories Europe to assess whether installing Delta-Xero filtration on a landfill gas engine would negatively affect lubricant condition, additive performance, or expected oil drain intervals.

View Case Study
contact us

Ready to transform your oil management?