Large hydraulic compression moulding press in a manufacturing plant

3,000 Ton Hydraulic Press: Overcurrent Shutdowns Eliminated

Hydraulic press oil on a 3,000 ton press: 97% fewer ≥4 µm particles, 75% lower MPC and no more overcurrent shutdowns.

Large hydraulic compression moulding press in a manufacturing plant
case study

How offline filtration stopped overcurrent shutdowns on a 3,000 ton hydraulic press

The Challenge

A 3,000 ton vertical compression moulding press in the United States was suffering repeated overcurrent shutdowns. Its tight valve clearances made it highly sensitive to fine particles, varnish and moisture in the hydraulic oil, leading to unplanned downtime, labour-intensive fault finding and unreliable production schedules.

The press ran on approximately 6,800 litres (1,800 US gal) of recycled AW 68 hydraulic oil in an elevated reservoir, with frequent top-ups because of leakage. Particle levels looked acceptable against older industry expectations, but MPC (varnish potential) was elevated at 15.4 and relative humidity measured 52.8%.

The Solution

A Delta-Xero offline submicron filtration system was connected to the hydraulic reservoir in a continuous kidney loop. The filter media targeted fine wear debris, contamination from the recycled oil, moisture and the oxidation products that form varnish on tight-tolerance valves.

Oil samples were taken before installation and after 35 days, tracking MPC, relative humidity, ISO 4406 cleanliness and particle counts at ≥4, ≥6 and ≥14 µm.

The Results

  • Zero shutdowns: no further overcurrent shutdowns were reported during the monitored period.

  • 97% fewer fine particles: particles ≥4 µm fell from 209,150 to 6,818 per mL, and ≥6 µm particles fell by 93%.

  • No large particles: the ≥14 µm count fell from 336 to zero.

  • Cleaner oil: ISO cleanliness improved from 18/14/9 to 13/10/0.

  • Less varnish and moisture: MPC fell from 15.4 to 3.8 and relative humidity from 52.8% to 13.2%, both 75% lower.

  • Longer component life: the cleanliness improvement indicated at least five times longer estimated component life.

Case study supplied by Kimbro. Download the full hydraulic press oil case study for the complete sample data.

Related Case Studies

About us - Delta-xero

Reduced iron levels and lower PQ index

A 1.5 MW wind turbine gearbox showed persistent contamination risk despite routine oil analysis. To understand the true internal condition of the gearbox, debris captured inside an offline filtration unit was analysed after extended in-service operation. Standard oil samples alone were not showing the full extent of varnish, wear debris, and moisture present within the system.  

View Case Study
Off-shore Oil and Gas: Case Study 2

The Additive Myth Debunked

A long-term independent study was carried out by POLARIS Laboratories Europe to assess whether installing Delta-Xero filtration on a landfill gas engine would negatively affect lubricant condition, additive performance, or expected oil drain intervals.

View Case Study
contact us

Ready to transform your oil management?